Session aimContinue with development of low Ip 1s AC pulse for cleaning purposes
Session day2025-04-24Operatorrhenriques
Session IDISTTOK_20250424_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
525242025-04-24 14:41:29.337rhenriques000Repeat | Pulse ran OK but data was not stored again
525232025-04-24 14:37:33.533rhenriques000Repeat with more semi-cycles (12) | Pulse ran OK, but no signals
525222025-04-24 14:28:09.133rhenriques-46.425Repeat with correct configuration | Not too bad, only one negative and 3 positive, BD did not happened
525212025-04-24 14:22:40.09rhenriques000Test AC40_2.cfg to assess reference configuration performance | Wrong MARTe configuration, no plasma
525202025-04-24 13:59:08.799rhenriques3.97.326Change programme, try maximum plasma current pulse, repeat 52450 | Ip is lower than in reference
525192025-04-24 13:43:31.924rhenriques1.23.317Repeat with further changes on Bv for BD | BD happens slightly earlier
525182025-04-24 13:39:07.532rhenriques1.23.317Repeat with further changes on Bv for BD | BD happens earlier
525172025-04-24 13:34:38.636rhenriques1.23.317Repeat with small tweak to Bv of BD | BD happens earlier
525162025-04-24 13:29:48.393rhenriques1.23.917Repeat with different Bv waveform for BD | BD happens later, but interesting result
525152025-04-24 13:08:06.879rhenriques1.22.717Changes on Bv for BD and changes on Bv, Bh for both positive and negative cycles | BD more slugish, inversion are worse
525142025-04-24 12:56:09.582rhenriques1.22.917Repeat with Bv changes for BD and for Ip>0 flattop | BD slightly later
525132025-04-24 12:44:37.544rhenriques1.22.817Repeat | Got some of the positive cycles back, BD starting slightly later
525122025-04-24 12:40:21.333rhenriques000Repeat for reference after lunch break | Controller failed, no plasma
525112025-04-24 10:59:53.399rhenriques1.22.6717Repeat with further changes of Bh for BD | Mostly the same as in previous, but Ip rises even slower
525102025-04-24 10:53:49.626rhenriques1.22.817Repeat with further changes on Bh for BD | BD starts earlier but Ip rise is slower
525092025-04-24 10:45:28.186rhenriques1.22.717Repeat with further changes of Bh for BD | BD happens slighlyt earlier than best previous result
525082025-04-24 10:39:12.679rhenriques1.22.917Repeat with further changes on Bh for BD | Still better than previous
525072025-04-24 10:34:13.062rhenriques1.2317Repeat with change of Bh in opposite direction | Better, slightly earlier than 52504
525062025-04-24 10:29:52.392rhenriques1.23.217Repeat reverting Bv as in previous pulse and changing Bh for BD | BD happens later
525052025-04-24 10:22:54.398rhenriques1.22.917Repeat with further changes of Bv for BD | BD happens later than previous
525042025-04-24 10:18:37.009rhenriques1.22.927Repeat with Bv adjustments in opposite direction | BD starts earlier
525032025-04-24 10:13:15.734rhenriques1.23.517Repeat with further adjustments on Bv for BD | Starts later than previous
525022025-04-24 10:08:46.355rhenriques1.23.517Repeat with adjustments on Bv for BD | BD a bit later
525012025-04-24 10:04:42.582rhenriques1.2317Repeat with adjustments on Bv for BD | BD starts earlier
525002025-04-24 09:58:23.86rhenriques1.23.117Repeat with further changes on Bh for BD | Mostly the same
524992025-04-24 09:50:18.331rhenriques1.2317Repeat with further changes on Bh for BD | Better but still not as good as the other ones
524982025-04-24 09:45:48.833rhenriques1.23.217Repeat with further adjustments to Bh for BD | Mostly the same as in previous
524972025-04-24 09:41:02.373rhenriques1.2317Repeat with changes on BD, going back to best results so far | BD happens later because Bh was not there in time
524962025-04-24 09:26:47.552rhenriques1.22.217Repeat delaying Bh | BD happens much later
524952025-04-24 09:18:21.841rhenriques1.22.417Changes on Bh for BD (starts earlier) | BD starts at same time, but plasma is less centered and Ip rise is slower
524942025-04-24 09:08:37.721rhenriques1.23.1517Bv changed for BD (starting earlier) and also for Ip<0 trying to get better position | BD happens at same time but Ip rise is faster, position still seems to be the same
524932025-04-24 08:55:50.916rhenriques1.23.117Repeat with changes on Bv for BD and going a bit back on Bv for Ip<0 flattop | BD slightly better (earlier), position is still quite off
524922025-04-24 08:45:35.053rhenriques1.2317Adjusting Bv for BD and Bv with further changes for Ip<0 flattop | BD happens much later, flattop position seem to be worse
524912025-04-24 08:33:21.552rhenriques1.22.717Repeat with Bh for BD changed and Bv for Ip<0 changed in opposite direction | BD starts earlier, more and longer negative cycles
524902025-04-24 08:22:41.34rhenriques1.22.217Repeat changing BD and adjusting position with Bv for Ip<0 | BD happens later, position seems to have gone to wrong direction
524892025-04-24 08:11:41.532rhenriques1.22.217Repeat 52487 for starting reference | Mostly the same as in reference pulse
524882025-04-24 07:53:22.552rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF | PF currents OK