Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52551 | 2025-04-30 17:56:29.887 | rhenriques | 1.4 | 3.8 | 26 | Repeat | OK |
| 52550 | 2025-04-30 17:39:41.635 | rhenriques | 1.4 | 3.9 | 26 | Repeat | OK, no drift observed |
| 52549 | 2025-04-30 17:34:18.304 | rhenriques | 1.4 | 3.8 | 26 | Repeat | OK |
| 52548 | 2025-04-30 17:30:13.452 | rhenriques | 1.4 | 3.8 | 26 | Repeat | Drift between pos and neg is present since quite early |
| 52547 | 2025-04-30 17:24:30.946 | rhenriques | 1.4 | 3.8 | 26 | Repeat | OK |
| 52546 | 2025-04-30 17:20:28.254 | rhenriques | 1.4 | 4 | 26 | Repeat | OK |
| 52545 | 2025-04-30 17:15:56.355 | rhenriques | 1.4 | 4 | 26 | Back to conditioning pulse, repeat 52542 | OK |
| 52544 | 2025-04-30 17:05:30.934 | rhenriques | 3 | 7 | 26 | Repeat with lower prefill pressure | Higher Ip but not significantly much higher, so condition is still not there |
| 52543 | 2025-04-30 16:56:57.672 | rhenriques | 2.45 | 6.1 | 26 | Repeat 52529 to assess maximum current available after a few pulses of conditioning | OK, but still far from reference before power outage (52446) |
| 52542 | 2025-04-30 16:44:39.78 | rhenriques | 1.4 | 4 | 26 | Repeat | OK, drift starts towards the end |
| 52541 | 2025-04-30 16:33:16.601 | rhenriques | 1.4 | 4 | 26 | Repeat | OK, no drift |
| 52540 | 2025-04-30 16:25:13.634 | rhenriques | 1.4 | 4.3 | 26 | Repeat | OK, but drift between pos and neg cicles is well present since early beginning |
| 52539 | 2025-04-30 16:16:55.596 | rhenriques | 1.4 | 4 | 26 | Repeat | OK, start drifting at the really end |
| 52538 | 2025-04-30 16:08:15.67 | rhenriques | 1.4 | 4.2 | 26 | Repeat | OK, no drift observed |
| 52537 | 2025-04-30 15:18:04.343 | rhenriques | 1.4 | 4.6 | 26 | Repeat | Drift still there |
| 52536 | 2025-04-30 15:12:19.285 | rhenriques | 1.4 | 4.6 | 26 | Repeat for conditioning | Drift between postitive and negative cycle reapeared |
| 52535 | 2025-04-30 14:56:28.415 | rhenriques | 1.4 | 4 | 26 | Repeat to check drift observed in previous pulse | drift no longer observed, positive and negative cycles much more alike |
| 52534 | 2025-04-30 14:51:08.845 | rhenriques | 1.4 | 4.6 | 26 | Repeat with 30 cycles (instead of 14) | All cycles despite increasing (shift) different behaviour between positive and negative cycles |
| 52533 | 2025-04-30 14:46:03.37 | rhenriques | 1.4 | 4.1 | 26 | Repeat with Spectrometer gain adjusted to match reference | lower pressure during pulse than in previous |
| 52532 | 2025-04-30 14:42:02.83 | rhenriques | 1.4 | 4.2 | 26 | Repeat 52389 (AC discharge at 1.3 kA) | All cycles worked, density is higher and gas pressure during pulse is higher than in reference, despite lower prefill pressure |
| 52531 | 2025-04-30 14:32:16.431 | rhenriques | -2.6 | 5.4 | 17 | Repeat 52232 (old 1s AC reference when plasma was dirty) | negative semicycles failed towards the end, Ip usually well above 1 kA so recipe for inversion may not work so well |
| 52530 | 2025-04-30 14:22:30.751 | rhenriques | 2.6 | 6.93 | 26 | Repeat with more cycles (6) | Only positive cycles |
| 52529 | 2025-04-30 14:17:59.206 | rhenriques | 2.7 | 6.3 | 26 | Repeat 52446 (high current pulse request) to assess conditionining | 1 kA and below but goes to 2.7 kA at the end |
| 52528 | 2025-04-30 14:12:26.922 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) | PF and TF currents OK |