Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52622 | 2025-05-05 18:19:40.868 | rhenriques | 3.5 | 6.6 | 26 | Repeat (4) 52604 to assess max Ip and wall conditionining | very similar to previous |
| 52621 | 2025-05-05 18:15:26.592 | rhenriques | 3.5 | 6.7 | 26 | Repeat (3) 52604 to assess max Ip and wall conditionining | Similar to previous pulse |
| 52620 | 2025-05-05 18:11:17.291 | rhenriques | 3.6 | 6.7 | 26 | Repeat (2) 52604 to assess max Ip and wall conditionining | generaly higher than reference |
| 52619 | 2025-05-05 18:06:39.895 | rhenriques | 4.2 | 7.2 | 26 | Repeat (1) 52604 to assess max Ip and wall conditionining | Higher peak current |
| 52618 | 2025-05-05 18:00:31.581 | rhenriques | 1.4 | 2.7 | 26 | Repeat (2) | OK, with failed semi-cycles |
| 52617 | 2025-05-05 17:56:29.081 | rhenriques | 1.4 | 2.8 | 26 | Repeat 52599 | Still cycles failing |
| 52616 | 2025-05-05 17:42:07.734 | rhenriques | 1.4 | 2.7 | 15 | Repeat with increased time for inversion and lower Bv (-240 A) | Still no inversion |
| 52615 | 2025-05-05 17:19:03.802 | rhenriques | 1.4 | 2.9 | 15 | Repeat, with further adjustments on Bv for transition to Ip<0 | still no 2nd semi-cycle |
| 52614 | 2025-05-05 17:14:10.544 | rhenriques | 1.4 | 2.4 | 15 | Repeat trying to obtain 2nd semi-cycle | Not sucessful |
| 52613 | 2025-05-05 17:00:38.89 | rhenriques | 1.4 | 2.8 | 15 | Repeat with some premag to bring the magnetisation down before breakdown (to prevent 1st cycle to saturate early) | Good, 1st cycle last the full length, check if it keeps like this from now on |
| 52612 | 2025-05-05 16:41:14.779 | rhenriques | 1.4 | 3.1 | 15 | Repeat trying to improve transitions to Ip> 0 | 1st cycle got short because or iron saturation |
| 52611 | 2025-05-05 16:33:31.441 | rhenriques | 1.4 | 2.1 | 15 | Repeat with further adjustments on Bv for Ip<0 | Still not there |
| 52610 | 2025-05-05 16:26:20.832 | rhenriques | 1.4 | 2.6 | 15 | Repeat with adjustments on plasma position for negative cycle (changing Bv) | Seem to have improved slighlty but inversion to Ip>0 not sucessful this time |
| 52609 | 2025-05-05 16:16:29.352 | rhenriques | 1.4 | 2.9 | 15 | Repeat with 14 cycles (instead of 8) and adjustment on Bv for transtion to Ip<0 | 3 sets of transtions from neg to pos but with failed cycles in between the sets, negative cycle position not centered |
| 52608 | 2025-05-05 16:11:21.501 | rhenriques | 0 | 0 | 0 | Repeat with 14 cycles (instead of 8) and adjustment on Bv for transtion to Ip<0 | Forgot to open gas, no plasma |
| 52607 | 2025-05-05 15:36:54.552 | rhenriques | 1.4 | 3.26 | 15 | Straight repeat to check if 1st cycle runs full programmed length 15 ms | Mostly the same as previous, but primary saturates later (1s cycle has probably run the full length) |
| 52606 | 2025-05-05 15:25:11.35 | rhenriques | 1.4 | 3.15 | 15 | Repeat with adjustments on transitions waveforms | one successful transition between neg. to pos., still many cycles failed |
| 52605 | 2025-05-05 14:56:49.286 | rhenriques | 1.4 | 2 | 15 | Repeat (1) 52599 for wall conditioning, trying shorter cycles to check if transitions are more successful | only 4 cycles out of 8, mainly positivie ones failed |
| 52604 | 2025-05-05 14:41:30.635 | rhenriques | 3.07 | 6.8 | 26 | Repeat (3) 52595 to assess max Ip and wall conditionining | More Ip than previous and reference throughout the pulse |
| 52603 | 2025-05-05 14:36:58.183 | rhenriques | 3 | 6.95 | 26 | Repeat (2) 52595 to assess max Ip and wall conditionining | Better, prefill pressure now closer to the one in reference |
| 52602 | 2025-05-05 14:31:57.948 | rhenriques | 2.6 | 6.7 | 26 | Repeat (1) 52595 to assess max Ip and wall conditionining | Mostly the same as in reference |
| 52601 | 2025-05-05 14:24:20.819 | rhenriques | 1.4 | 3 | 26 | Repeat (5) 52592 for wall conditioning, with feedback on plasma position (with electric probes), PID soft control | Again, badly controlled |
| 52600 | 2025-05-05 14:16:18.449 | rhenriques | 1.4 | 3.5 | 26 | Repeat (4.5) 52592 for wall conditioning, with feedback on plasma position (with electric probes), PID medium control | Plasma position not controlled properly |
| 52599 | 2025-05-05 13:58:32.225 | rhenriques | 1.4 | 3.4 | 26 | Repeat (4) 52592 for wall conditioning, with adjustments on Bh to center positive cycle a bit better | improved for 1st cycle |
| 52598 | 2025-05-05 13:37:47.532 | rhenriques | 1.4 | 2.9 | 26 | Repeat (3) 52592 for wall conditioning but without Ip variations | Still many cycles failing, may be due to lack of plasma position centering |
| 52597 | 2025-05-05 13:25:23.303 | rhenriques | 1.4 | 2.7 | 26 | Repeat (2) 52592 for wall conditioning, with adjustments on fields to center positive cycle a bit better | posititive cycles keep failing and transitions are clrearly not optimized |
| 52596 | 2025-05-05 13:13:57.905 | rhenriques | 1.4 | 2.5 | 26 | Repeat (1) 52592 for wall conditioning | OK, but cycles are failing a bit, postive cycle seems to loose centering position |
| 52595 | 2025-05-05 13:05:19.145 | rhenriques | 2.8 | 6.6 | 26 | Repeat (3) 52585 to assess max Ip and wall conditionining | Slightly better than previous (prefill pressure was lower) and a bit better than reference |
| 52594 | 2025-05-05 12:59:55.206 | rhenriques | 2.7 | 6.7 | 26 | Repeat (2) 52585 to assess max Ip and wall conditionining | lower max Ip, but slighlty longer and higher throughout |
| 52593 | 2025-05-05 12:54:22.283 | rhenriques | 3 | 7 | 26 | Repeat (1) 52585 to assess max Ip and wall conditionining | Slightly better than reference |
| 52592 | 2025-05-05 12:41:26.103 | rhenriques | 1.4 | 3.2 | 26 | Repeat (5) | still some cycles failing |
| 52591 | 2025-05-05 12:36:02.859 | rhenriques | 1.4 | 3 | 26 | Repeat (4) | OK, but cycles are failing more |
| 52590 | 2025-05-05 12:31:50.999 | rhenriques | 1.4 | 2.3 | 26 | Repeat (3) | OK, prefill pressure higher than previous pulses |
| 52589 | 2025-05-05 10:58:33.332 | rhenriques | 1.4 | 3.2 | 26 | Repeat (2) | Prefill pressure may not be stable during pulse |
| 52588 | 2025-05-05 10:54:17.975 | rhenriques | 1.4 | 2.6 | 26 | Repeat (1) 52584 for wall conditioning | OK |
| 52587 | 2025-05-05 10:41:17.015 | rhenriques | 2.6 | 6.6 | 26 | Repeat (3) | Mostly the same as in previous |
| 52586 | 2025-05-05 10:36:33.799 | rhenriques | 2.6 | 6.6 | 26 | Repeat (2) | OK, slightly better (more stable Ip) |
| 52585 | 2025-05-05 10:32:12.684 | rhenriques | 2.6 | 6.5 | 26 | Repeat 52577 to assess max Ip and wall conditionining | Better, higher Ip overall and a bit longer |
| 52584 | 2025-05-05 10:24:38.922 | rhenriques | 1.4 | 3.3 | 26 | Repeat | OK |
| 52583 | 2025-05-05 10:20:25.814 | rhenriques | 1.4 | 3.3 | 26 | Repeat | OK |
| 52582 | 2025-05-05 10:16:26.482 | rhenriques | 1.4 | 3.4 | 26 | Repeat | OK |
| 52581 | 2025-05-05 10:12:24.861 | rhenriques | 1.4 | 3.3 | 26 | Repeat | OK |
| 52580 | 2025-05-05 10:08:17.321 | rhenriques | 1.4 | 3.46 | 26 | Plasma pulse for wall conditioning, repeat 52571 | OK |
| 52579 | 2025-05-05 10:00:31.992 | rhenriques | 1.8 | 5.9 | 26 | Repeat | Mostly the same behaviour as in the previous pulse |
| 52578 | 2025-05-05 09:56:28.476 | rhenriques | 1.74 | 5.6 | 26 | Repeat | Higher Ip throughout |
| 52577 | 2025-05-05 09:52:10.181 | rhenriques | 1.46 | 5 | 26 | Repeat 52575 to assess max Ip and wall conditionining | current during flattop just abtou 1 kA, need a repeat as this one was first pulse of the day |
| 52576 | 2025-05-05 09:40:05.736 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF | PF currents OK |