Session aimSpecial dryrun for TF pickup acquisition on Magnetics signals and then plasmas for vessel conditioning
Session day2025-05-06Operatorrhenriques
Session IDISTTOK_20250506_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
526312025-05-06 15:43:28.04rhenriques1.42.715Repeat (2) 52616 for wall conditioning, with mods on Bh for inversion to Ip<0 trying to get 2nd semi-cycle, HIBID valve open | Still no 2nd semi-cycle
526302025-05-06 15:32:33.224rhenriques1.42.615Repeat (1) 52616 for wall conditioning, with HBID valve open | OK, one sucessfull inversion from neg to pos
526292025-05-06 15:18:36.093rhenriques3.36.926Repeat (3) 52622 to assess max Ip and wall conditionining | Mostly similar to previous but shorter
526282025-05-06 15:11:51.538rhenriques3.36.726Repeat (2) 52622 to assess max Ip and wall conditionining | Still lower Ip than reference but higher the in previous pulse
526272025-05-06 15:06:14.11rhenriques36.826Repeat (1) 52622 to assess max Ip and wall conditionining | Lower Ip than in reference
526262025-05-06 14:47:54.958rhenriques000Repeat with PF currents | OK
526252025-05-06 14:36:36.927rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) TF only, no PF | OK
526242025-05-06 14:29:21.869rhenriques000Repeat with a longer delayed start (1 s instead of 0.75 s) | Good
526232025-05-06 14:24:04.795rhenriques000Special dryrun (file: dryrun_special_no_PF_delayed_start.cfg) for TF pickup on Mirnov coils (catch TF ramp-down), no PF currents, TF only | Good