Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52631 | 2025-05-06 15:43:28.04 | rhenriques | 1.4 | 2.7 | 15 | Repeat (2) 52616 for wall conditioning, with mods on Bh for inversion to Ip<0 trying to get 2nd semi-cycle, HIBID valve open | Still no 2nd semi-cycle |
| 52630 | 2025-05-06 15:32:33.224 | rhenriques | 1.4 | 2.6 | 15 | Repeat (1) 52616 for wall conditioning, with HBID valve open | OK, one sucessfull inversion from neg to pos |
| 52629 | 2025-05-06 15:18:36.093 | rhenriques | 3.3 | 6.9 | 26 | Repeat (3) 52622 to assess max Ip and wall conditionining | Mostly similar to previous but shorter |
| 52628 | 2025-05-06 15:11:51.538 | rhenriques | 3.3 | 6.7 | 26 | Repeat (2) 52622 to assess max Ip and wall conditionining | Still lower Ip than reference but higher the in previous pulse |
| 52627 | 2025-05-06 15:06:14.11 | rhenriques | 3 | 6.8 | 26 | Repeat (1) 52622 to assess max Ip and wall conditionining | Lower Ip than in reference |
| 52626 | 2025-05-06 14:47:54.958 | rhenriques | 0 | 0 | 0 | Repeat with PF currents | OK |
| 52625 | 2025-05-06 14:36:36.927 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) TF only, no PF | OK |
| 52624 | 2025-05-06 14:29:21.869 | rhenriques | 0 | 0 | 0 | Repeat with a longer delayed start (1 s instead of 0.75 s) | Good |
| 52623 | 2025-05-06 14:24:04.795 | rhenriques | 0 | 0 | 0 | Special dryrun (file: dryrun_special_no_PF_delayed_start.cfg) for TF pickup on Mirnov coils (catch TF ramp-down), no PF currents, TF only | Good |