Session aimContinue with plasma pulses for conditioning
Session day2025-05-07Operatorrhenriques
Session IDISTTOK_20250507_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
526702025-05-07 19:24:34.044rhenriques5.1826Repeat with Bv adjustments for Ip<0 and adding 2 more cycles (4 in total) | Inversion to Ip>0 not successful, neg. cycles is worse
526692025-05-07 19:17:01.538rhenriques-57.826Repeat with adjustments on Bv for both pos. and neg. cycles | neg. cycle position seems worse
526682025-05-07 19:08:45.69rhenriques-4.65826Repeat with Bh adjustments for position in both pos. and neg. cycles | BD happens at the right time (much earlier), position changed a bit
526672025-05-07 18:57:38.06rhenriques-4.97.526Repeat with Bh adjustments for Ip>0 position and Bv changes for inversion to Ip<0 | Successful inversion
526662025-05-07 18:50:38.546rhenriques4.66.726Repeat with Bv changes on BD to improve Ip ramp up | BD happens earlier
526652025-05-07 18:45:47.047rhenriques4.76.825Straight repeat at higher prefill pressure | Mostly the same Ip altough BD starts later
526642025-05-07 18:40:50.355rhenriques4.77.326Repeat (7) previous to assess max Ip and wall conditionining, with further changes on Bv for position and Bh inversion to Ip<0 | Very similar to previous, Ip a bit more stable
526632025-05-07 18:32:10.691rhenriques4.77.2526Repeat (6) previous to assess max Ip and wall conditionining, with further changes on Bv for position | Higher Ip throughout and longer, prefill slighlty lower
526622025-05-07 18:26:51.873rhenriques4.67.126Repeat (5) previous to assess max Ip and wall conditionining, with further changes on Bv for position | Higher Ip throught and longer pulse
526612025-05-07 18:21:46.669rhenriques4.67.426Repeat (4) previous to assess max Ip and wall conditionining, with further changes on Bv for position and inversion | Slightly better than previous, although same peak current, but longer pulse
526602025-05-07 18:15:08.987rhenriques4.67.726Repeat (3) previous to assess max Ip and wall conditionining, with further changes on Bv | slightly better than previous
526592025-05-07 18:09:16.688rhenriques4.6826 Repeat (2) 52652 to assess max Ip and wall conditionining, with adjustments Bv for Ip>0 | Longer pulse and higher Ip throughout, but a bit lower prefill pressure
526582025-05-07 18:01:43.999rhenriques4.5826Repeat (1) 52652 to assess max Ip and wall conditionining | Similar to reference, but higher peak current
526572025-05-07 17:56:30.741rhenriques1.42.726Repeat (5) 52649 for wall conditioning | OK
526562025-05-07 17:49:28.259rhenriques1.42.626Repeat (4) 52649 for wall conditioning, with adjusted Bv for Ip<0 | OK, position did not seem to have changed much
526552025-05-07 17:42:28.017rhenriques1.42.726Repeat (3) 52649 for wall conditioning | Very few positive cycles and short negative ones
526542025-05-07 17:38:29.685rhenriques1.42.626Repeat (2) 52649 for wall conditioning | Fewer successful cycles then previous
526532025-05-07 17:34:30.969rhenriques1.42.526Repeat (1) 52649 for wall conditioning | OK
526522025-05-07 17:30:18.725rhenriques4.17.126Repeat (3) 52644 to assess max Ip and wall conditionining | Very similar to previous
526512025-05-07 17:26:13.537rhenriques4.2726Repeat (2) 52644 to assess max Ip and wall conditionining | Similar to previous
526502025-05-07 17:22:09.733rhenriques4.157.2626Repeat (1) 52644 to assess max Ip and wall conditionining | Slightly better than previous
526492025-05-07 17:17:28.393rhenriques1.42.726Repeat (5) 52641 for wall conditioning | Similar to previous
526482025-05-07 17:13:28.941rhenriques1.42.726Repeat (4) 52641 for wall conditioning | OK, same-ish
526472025-05-07 17:09:31.369rhenriques1.42.6526Repeat (3) 52641 for wall conditioning | OK, slightly better, back to something similar to the reference
526462025-05-07 17:05:16.405rhenriques1.42.726Repeat (2) 52641 for wall conditioning | Not so good, less sucessful cycles than previous
526452025-05-07 17:01:15.113rhenriques1.42.726Repeat (1) 52641 for wall conditioning | OK, similar to reference
526442025-05-07 16:55:35.846rhenriques4726Repeat (3) 52636 to assess max Ip and wall conditionining | Very similar to previous, but higher peak current
526432025-05-07 16:49:45.739rhenriques3.88726Repeat (2) 52636 to assess max Ip and wall conditionining | Similar to previous but longer
526422025-05-07 16:45:48.015rhenriques3.85726Repeat (1) 52636 to assess max Ip and wall conditionining | Better than reference
526412025-05-07 16:41:29.603rhenriques1.42.726Repeat (5) 52618 for wall conditioning | OK, same
526402025-05-07 16:37:31.831rhenriques1.42.626Repeat (4) 52618 for wall conditioning | OK, same
526392025-05-07 16:33:31.307rhenriques1.42.726Repeat (3) 52618 for wall conditioning | OK, same
526382025-05-07 16:29:31.791rhenriques1.42.726Repeat (2) 52618 for wall conditioning | Moslty the same as in previous
526372025-05-07 16:25:01.651rhenriques1.42.826Repeat (1) 52618 for wall conditioning | many failed pulses, but hopefully it is still conditioning the limiters
526362025-05-07 16:15:08.86rhenriques3.66.826Repeat (3) 52629 to assess max Ip and wall conditionining | Similar to previous despite going to higher current
526352025-05-07 16:11:10.879rhenriques3.46.626Repeat (2) 52629 to assess max Ip and wall conditionining | slightly better than ref and previuos but not much better, prefill pressure was also lower
526342025-05-07 16:07:08.90rhenriques3.26.926Repeat (1) 52629 to assess max Ip and wall conditionining | Similar to reference
526332025-05-07 15:46:14.016rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF | PF currents OK
526322025-05-07 15:37:45.058rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF | MARTe configuration not loaded