Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52769 | 2025-05-22 16:36:04.082 | rhenriques | -4.1 | 5.4 | 18 | Repeat | OK, Tomography OUT still not providing signals, needs checking |
| 52768 | 2025-05-22 16:22:41.234 | rhenriques | -4.1 | 5.4 | 18 | Repeat, Tomography OUT being acquired | OK, Ip with same behaviour |
| 52767 | 2025-05-22 16:13:27.234 | rhenriques | -4.3 | 5.6 | 18 | Repeat, Tomography BOT being acquired | OK, Ip with same behaviour |
| 52766 | 2025-05-22 16:02:20.523 | rhenriques | -4.1 | 5.45 | 18 | Repeat, filter back to 16 kHz, tomography TOP being acquired | Ip decreases throughout the pulse, impurity signal keeps being high and even a bit higher than previous pulse |
| 52765 | 2025-05-22 15:53:12.611 | rhenriques | -4.22 | 0 | 18 | Repeat, filter for inferferometer signals set to 8 kHz | Density signal is wrong, Ip keeps decreasing during pulse, optical signal for O at 780 nm keeps increasing |
| 52764 | 2025-05-22 15:45:38.786 | rhenriques | -4.25 | 5.4 | 18 | Repeat | OK |
| 52763 | 2025-05-22 15:38:15.912 | rhenriques | -4.5 | 5.7 | 18 | Repeat with 40 semi-cycles | Ip decreases significantly towards the end as O line optical signal increases |
| 52762 | 2025-05-22 15:31:10.062 | rhenriques | -4.1 | 6.1 | 18 | Repeat with 20 semi-cycles | OK |
| 52761 | 2025-05-22 15:25:13.275 | rhenriques | -4.5 | 5.7 | 18 | Plasma pulse for conditioning, repeat 52732 | OK, lower Ip than reference |
| 52760 | 2025-05-22 15:12:57.916 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) | OK |
| 52759 | 2025-05-22 15:02:33.71 | rhenriques | 0 | 0 | 0 | Repeat | OK |
| 52758 | 2025-05-22 14:58:32.474 | rhenriques | 0 | 0 | 0 | Repeat | OK |
| 52757 | 2025-05-22 14:54:33.141 | rhenriques | 0 | 0 | 0 | Repeat | OK |
| 52756 | 2025-05-22 14:47:31.683 | rhenriques | 0 | 0 | 0 | Repeat | OK |
| 52755 | 2025-05-22 14:39:18.898 | rhenriques | 0 | 0 | 0 | Special dryrun for TF pickup on Mirnov coils (catch TF ramp-down) and also for HIBD bem direction sweep, repeat 52698, no PF currents, TF only | OK |
| 52754 | 2025-05-22 14:27:51.26 | rhenriques | 0 | 0 | 0 | Repeat | OK |
| 52753 | 2025-05-22 14:23:52.304 | rhenriques | 0 | 0 | 0 | Repeat | HIBD valve was closed |
| 52752 | 2025-05-22 14:19:31.499 | rhenriques | 0 | 0 | 0 | Repeat | OK |
| 52751 | 2025-05-22 14:15:11.231 | rhenriques | 0 | 0 | 0 | Repeat | Real-time controller failed, no data acquired |
| 52750 | 2025-05-22 14:09:05.34 | rhenriques | 0 | 0 | 0 | Repeat with Tomography OUT channels connected to B3 ch9-16 and ch25-32 | OK |
| 52749 | 2025-05-22 13:56:02.608 | rhenriques | 0 | 0 | 0 | Repeat, HIBD with beam injection into torus | OK |
| 52748 | 2025-05-22 13:48:41.987 | rhenriques | 0 | 0 | 0 | Repeat with HIBD valve open | OK |
| 52747 | 2025-05-22 13:44:39.854 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) TF only for HIBD, HIBD valve close, Tomography BOT acquired in B3ch9-16 and B3ch25-32 | OK |