Session aimPlasma pulses for HIBD, Tomography and conditioning
Session day2025-05-22Operatorrhenriques
Session IDISTTOK_20250522_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
527692025-05-22 16:36:04.082rhenriques-4.15.418Repeat | OK, Tomography OUT still not providing signals, needs checking
527682025-05-22 16:22:41.234rhenriques-4.15.418Repeat, Tomography OUT being acquired | OK, Ip with same behaviour
527672025-05-22 16:13:27.234rhenriques-4.35.618Repeat, Tomography BOT being acquired | OK, Ip with same behaviour
527662025-05-22 16:02:20.523rhenriques-4.15.4518Repeat, filter back to 16 kHz, tomography TOP being acquired | Ip decreases throughout the pulse, impurity signal keeps being high and even a bit higher than previous pulse
527652025-05-22 15:53:12.611rhenriques-4.22018Repeat, filter for inferferometer signals set to 8 kHz | Density signal is wrong, Ip keeps decreasing during pulse, optical signal for O at 780 nm keeps increasing
527642025-05-22 15:45:38.786rhenriques-4.255.418Repeat | OK
527632025-05-22 15:38:15.912rhenriques-4.55.718Repeat with 40 semi-cycles | Ip decreases significantly towards the end as O line optical signal increases
527622025-05-22 15:31:10.062rhenriques-4.16.118Repeat with 20 semi-cycles | OK
527612025-05-22 15:25:13.275rhenriques-4.55.718Plasma pulse for conditioning, repeat 52732 | OK, lower Ip than reference
527602025-05-22 15:12:57.916rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) | OK
527592025-05-22 15:02:33.71rhenriques000Repeat | OK
527582025-05-22 14:58:32.474rhenriques000Repeat | OK
527572025-05-22 14:54:33.141rhenriques000Repeat | OK
527562025-05-22 14:47:31.683rhenriques000Repeat | OK
527552025-05-22 14:39:18.898rhenriques000Special dryrun for TF pickup on Mirnov coils (catch TF ramp-down) and also for HIBD bem direction sweep, repeat 52698, no PF currents, TF only | OK
527542025-05-22 14:27:51.26rhenriques000Repeat | OK
527532025-05-22 14:23:52.304rhenriques000Repeat | HIBD valve was closed
527522025-05-22 14:19:31.499rhenriques000Repeat | OK
527512025-05-22 14:15:11.231rhenriques000Repeat | Real-time controller failed, no data acquired
527502025-05-22 14:09:05.34rhenriques000Repeat with Tomography OUT channels connected to B3 ch9-16 and ch25-32 | OK
527492025-05-22 13:56:02.608rhenriques000Repeat, HIBD with beam injection into torus | OK
527482025-05-22 13:48:41.987rhenriques000Repeat with HIBD valve open | OK
527472025-05-22 13:44:39.854rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) TF only for HIBD, HIBD valve close, Tomography BOT acquired in B3ch9-16 and B3ch25-32 | OK