|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52944 | 2025-06-03 16:11:09.673 | rhenriques | -4.4 | 5.1 | 18 | Continue with position corrections and small adjustment to the the inversion waveform to Ip>0 | Ip for neg semi cycle is higher than in previous |
| 52943 | 2025-06-03 16:04:00.973 | rhenriques | -4.2 | 5.12 | 18 | Repeat trying to improve position of negative semi-cycle | position is better |
| 52942 | 2025-06-03 15:54:35.399 | rhenriques | -4.4 | 4.9 | 18 | Repeat 52904, plasma pulse with shorter semi-cycle duration for machine conditioning, 14 semi-cycles | similar to reference |
| 52941 | 2025-06-03 15:42:40.577 | rhenriques | -4.6 | 4.8 | 26 | Repeat (3) 52901 to assess max Ip and wall conditioning | Slightly better than previous but still not as good as the reference one |
| 52940 | 2025-06-03 15:35:38.432 | rhenriques | -4.4 | 4.7 | 26 | Repeat (2) 52901 to assess max Ip and wall conditioning | Better, closer to reference but still below |
| 52939 | 2025-06-03 15:30:18.256 | rhenriques | -4.1 | 4.4 | 26 | Repeat (1) 52901 to assess max Ip and wall conditioning (first plasma pulse with MARTe with MLControlGAM) | Significantly lower Ip throughout than in reference |
| 52938 | 2025-06-03 15:14:54.625 | rhenriques | 0 | 0 | 0 | Repeat with TF and PF currents, dryrun (file: dryrun_standard_2025_04_04_52149.cfg) | OK |
| 52937 | 2025-06-03 15:01:01.87 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF, no PF, ISTTOK GAMs with MLControlGAM | OK |
| 52936 | 2025-06-03 13:19:05.594 | rhenriques | 0 | 0 | 0 | Repeat 52930 with on-coil current | Good |
| 52935 | 2025-06-03 13:14:50.901 | rhenriques | 0 | 0 | 0 | Straight repeat (without loading a new cfg file) to check if change to the GAM resolved the issue | Good, changes seem to have solved the problem |
| 52934 | 2025-06-03 13:10:35.361 | rhenriques | 0 | 0 | 0 | Repeat with another different correction of Plasma ended time in FireSignalDischargeStatusGAM: reseting EndedTime during PRE | OK |
| 52933 | 2025-06-03 13:01:29.352 | rhenriques | 0 | 0 | 0 | Repeat with different correction of Plasma ended time in FireSignalDischargeStatusGAM | OK, but PlasmaEndedTime gets reset just after the pulse, so value in HTTP page does not remain there |
| 52932 | 2025-06-03 12:49:58.531 | rhenriques | 0 | 0 | 0 | Straight repeat (without loading a new cfg file) to check if change to the GAM resolved the issue | Did not work as it seems MARTe is not reloading the GAMs |
| 52931 | 2025-06-03 12:44:58.558 | rhenriques | 0 | 0 | 0 | Repeat with correction of Plasma ended time in FireSignalDischargeStatusGAM so that MARTeNode would always recognize the plasma termination | OK |
| 52930 | 2025-06-03 12:19:10.077 | rhenriques | 0 | 0 | 0 | Repeat for primary field circuit but without on-coil current | OK |
| 52929 | 2025-06-03 12:11:56.042 | rhenriques | 0 | 0 | 0 | Repeat with on-coil current | Good |
| 52928 | 2025-06-03 12:03:14.548 | rhenriques | 0 | 0 | 0 | Repeat 52927 (last pulse from previous session) with ML control (mode 9) during 2 ms for the Vertical Field current, informatic pulse only, no real currents yet | OK |