Session aimContinue with commissioning tests for MLControlGAM and MARTe, maybe plasma afterwards
Session day2025-06-03Operatorrhenriques
Session IDISTTOK_20250603_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
529442025-06-03 16:11:09.673rhenriques-4.45.118Continue with position corrections and small adjustment to the the inversion waveform to Ip>0 | Ip for neg semi cycle is higher than in previous
529432025-06-03 16:04:00.973rhenriques-4.25.1218Repeat trying to improve position of negative semi-cycle | position is better
529422025-06-03 15:54:35.399rhenriques-4.44.918Repeat 52904, plasma pulse with shorter semi-cycle duration for machine conditioning, 14 semi-cycles | similar to reference
529412025-06-03 15:42:40.577rhenriques-4.64.826Repeat (3) 52901 to assess max Ip and wall conditioning | Slightly better than previous but still not as good as the reference one
529402025-06-03 15:35:38.432rhenriques-4.44.726Repeat (2) 52901 to assess max Ip and wall conditioning | Better, closer to reference but still below
529392025-06-03 15:30:18.256rhenriques-4.14.426Repeat (1) 52901 to assess max Ip and wall conditioning (first plasma pulse with MARTe with MLControlGAM) | Significantly lower Ip throughout than in reference
529382025-06-03 15:14:54.625rhenriques000Repeat with TF and PF currents, dryrun (file: dryrun_standard_2025_04_04_52149.cfg) | OK
529372025-06-03 15:01:01.87rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF, no PF, ISTTOK GAMs with MLControlGAM | OK
529362025-06-03 13:19:05.594rhenriques000Repeat 52930 with on-coil current | Good
529352025-06-03 13:14:50.901rhenriques000Straight repeat (without loading a new cfg file) to check if change to the GAM resolved the issue | Good, changes seem to have solved the problem
529342025-06-03 13:10:35.361rhenriques000Repeat with another different correction of Plasma ended time in FireSignalDischargeStatusGAM: reseting EndedTime during PRE | OK
529332025-06-03 13:01:29.352rhenriques000Repeat with different correction of Plasma ended time in FireSignalDischargeStatusGAM | OK, but PlasmaEndedTime gets reset just after the pulse, so value in HTTP page does not remain there
529322025-06-03 12:49:58.531rhenriques000Straight repeat (without loading a new cfg file) to check if change to the GAM resolved the issue | Did not work as it seems MARTe is not reloading the GAMs
529312025-06-03 12:44:58.558rhenriques000Repeat with correction of Plasma ended time in FireSignalDischargeStatusGAM so that MARTeNode would always recognize the plasma termination | OK
529302025-06-03 12:19:10.077rhenriques000Repeat for primary field circuit but without on-coil current | OK
529292025-06-03 12:11:56.042rhenriques000Repeat with on-coil current | Good
529282025-06-03 12:03:14.548rhenriques000Repeat 52927 (last pulse from previous session) with ML control (mode 9) during 2 ms for the Vertical Field current, informatic pulse only, no real currents yet | OK