Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52996 | 2025-06-09 18:09:31.507 | rhenriques | -5.8 | 6.3 | 26 | Repeat with 6 semi-cycles | OK, 1st neg. cycles is back |
| 52995 | 2025-06-09 18:05:29.574 | rhenriques | 5.2 | 6 | 26 | Straight repeat aiming for BD as usual ones | BD more similar to usual but still no 1st neg. cycle |
| 52994 | 2025-06-09 17:58:48.724 | rhenriques | 5.4 | 6.8 | 26 | Repeat with increased Ip limit for neg. cycles and adjusting Bh for neg. cycle | lost 1st neg. cycle again, BD started earlier than usual |
| 52993 | 2025-06-09 17:50:16.795 | rhenriques | -5.5 | 6.6 | 26 | Straight repeat | very similar to previous |
| 52992 | 2025-06-09 17:45:35.351 | rhenriques | -5.5 | 6.5 | 26 | Repeat trying to recover negative cycle | Ip of neg cycle being limited |
| 52991 | 2025-06-09 17:36:19.303 | rhenriques | 5.27 | 6.2 | 26 | Repeat trying to optimize the position | lost 1st inversion (1st negative cycle) |
| 52990 | 2025-06-09 17:28:33.453 | rhenriques | -5.4 | 6.4 | 26 | Repeat with increased Ip limit for both positive and negative cycles | OK |
| 52989 | 2025-06-09 17:20:29.355 | rhenriques | 5.2 | 6 | 26 | Repeat by increasing Ip limit | Both positive and negative Ip are being limited |
| 52988 | 2025-06-09 17:12:04.547 | rhenriques | 4.9 | 6.2 | 26 | Repeat without position changes as 52978 | OK, Ip is limited in positive cycle |
| 52987 | 2025-06-09 16:48:18.958 | rhenriques | -5.1 | 6 | 26 | Repeat for conditioning | 4 semi-cycles out of 6 |
| 52986 | 2025-06-09 16:33:07.891 | rhenriques | -5.15 | 6 | 26 | Repeat with position change for negative cyle in opposite direction | Better, clear change in position is observed |
| 52985 | 2025-06-09 16:22:25.988 | rhenriques | 4.9 | 6 | 26 | Repeat with position change in negative cycle as well and trying 6 semi-cycles | Position change for neg. cycle terminated the plasma early |
| 52984 | 2025-06-09 16:04:24.844 | rhenriques | -5.2 | 6.1 | 26 | Repeat with increased change | OK, change in position is more enhanced |
| 52983 | 2025-06-09 15:54:36.307 | rhenriques | -5.1 | 6 | 26 | Repeat with position change in opposite direction | OK, position changes |
| 52982 | 2025-06-09 15:38:57.952 | rhenriques | -5.2 | 6.8 | 26 | Repeat with change in opposite directly and starting 5 ms later (at 10 ms) | OK, clear change in position is observed |
| 52981 | 2025-06-09 15:25:59.283 | rhenriques | 4.9 | 5.9 | 26 | Repeat 52978, with radial position change | No clear position change observed as request was too early in the cycle, |
| 52980 | 2025-06-09 15:10:32.355 | rhenriques | 3 | 3.75 | 18 | Repeat with change in inversion to Ip<0 waveform for vertical field | still mostly the same result |
| 52979 | 2025-06-09 14:57:59.113 | rhenriques | 3 | 3.6 | 18 | Repeat 52957, plasma for wall conditioning, 3 kA feedback, 18 ms long semi-cycle and 10 semi-cycles | many cycles failed |
| 52978 | 2025-06-09 14:51:39.783 | rhenriques | -5.1 | 5.8 | 26 | Repeat (4) 52972 to assess max Ip and wall conditioning | OK, Ip sill below reference |
| 52977 | 2025-06-09 14:41:59.074 | rhenriques | -5 | 5.7 | 26 | Repeat (3) 52972 to assess max Ip and wall conditioning, tomography ON: top at RT1ch1_16 and bot at RT1ch17_24 and B3ch9_16 | Getting closer to the reference, but still a bit lower |
| 52976 | 2025-06-09 14:28:13.498 | rhenriques | -4.95 | 5.7 | 26 | Repeat (2) 52972 to assess max Ip and wall conditioning | Better than previous but still below reference |
| 52975 | 2025-06-09 14:23:33.067 | rhenriques | -4.78 | 5.2 | 26 | Repeat (1) 52972 to assess max Ip and wall conditioning | Lower Ip than in reference |
| 52974 | 2025-06-09 14:15:26.932 | rhenriques | 0 | 0 | 0 | Repeat with TF and PF currents | TF and PF currents OK |
| 52973 | 2025-06-09 14:04:37.526 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg), no TF and no PF, tesing timing board | OK |