Session aimPlasma pulses for conditioning and tests for density signals and magnetics integrators
Session day2025-07-16Operatorrhenriques
Session IDISTTOK_20250716_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
531902025-07-16 16:46:37.517rhenriques1.33.517Repeat | OK
531892025-07-16 16:31:01.058rhenriques1.33.517Repeat 53173 for conditioning (1.3 kA, 50 cycles of 17 ms) | OK
531882025-07-16 16:19:14.972rhenriques3.44.326Repeat, IPLB raw signal acquired in B3ch29 | ISIN signal OK, Ip similar to previous but a bit better
531872025-07-16 16:12:01.402rhenriques3.774.226Repeat, IPLA raw signal acquired in B3ch29 | Signals look OK, plasma had more successful cycles
531862025-07-16 16:05:39.391rhenriques-3.54.226Repeat with cables swapped back to correct position | Signals OK, plasma very similar to previous
531852025-07-16 15:57:39.357rhenriques-3.464.226Repeat, with ICOS raw signal acquired in RT3ch15 and B3ch29 (2 MSsp) | RT3ch15 channel not working, forgot to swap cable so default ICOS and ISIN in MARTe chs were swapped
531842025-07-16 15:47:13.939rhenriques-3.24.126Repeat (3) 53101 to assess max Ip and wall conditioning, acquire ISIN raw signal in RT3ch15 and B3ch29 (2 MSps) | Ip around 2.3 kA and cycle length still shorter than reference
531832025-07-16 15:24:13.416rhenriques1.33.517Repeat, ISIN (plasma position) raw signal in RT3ch14 and using ICOS integrator for analog integration | There is signal in ISIN but it also looks quite small, plasma keeps evolving
531822025-07-16 15:01:18.555rhenriques1.33.817Repeat, ICOS (plasma position) raw signal connected to RT3ch14 | ICOS signal OK, but seem quite low amplitude compared with EO level, plasma keeps evolving
531812025-07-16 14:50:44.316rhenriques1.33.617Repeat, IPLA raw signal acquired in RT3ch14 (chopper) and integrated (analog) signal in RT2ch4 | IPLA signal looks OK, impurities and plasma temperature keeps evolving
531802025-07-16 14:41:32.821rhenriques1.33.817Repeat, IPLB raw signal connected to RT3ch14 (previously was RT3ch13) | IPLB signal looks reasonable, but needs further checks and filtering
531792025-07-16 14:12:05.555rhenriques1.33.817Repeat, revert changes on density signals | Density signal is OK, impurities and plama temperature keeps evolving
531782025-07-16 14:01:49.915rhenriques1.3417Repeat, density signals SINE and COSINE swapped at ATCA board entry to tests ADC channels | Both ADC channels are working, density signal is back (but inverted)
531772025-07-16 13:51:10.804rhenriques1.3017Repeat 53173 for conditioning (1.3 kA, 50 cycles of 17 ms) | OK, similar to reference
531762025-07-16 13:44:51.273rhenriques-2.1026Repeat (2) 53101 to assess max Ip and wall conditioning | Slightly better than previous
531752025-07-16 13:39:59.731rhenriques1.8026Repeat (1) 53101 to assess max Ip and wall conditioning | Better than last one like this 53167, but still quite far from reference 53101, density signal still not working
531742025-07-16 13:31:19.695rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg), no TF | PF currents OK