Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 53190 | 2025-07-16 16:46:37.517 | rhenriques | 1.3 | 3.5 | 17 | Repeat | OK |
| 53189 | 2025-07-16 16:31:01.058 | rhenriques | 1.3 | 3.5 | 17 | Repeat 53173 for conditioning (1.3 kA, 50 cycles of 17 ms) | OK |
| 53188 | 2025-07-16 16:19:14.972 | rhenriques | 3.4 | 4.3 | 26 | Repeat, IPLB raw signal acquired in B3ch29 | ISIN signal OK, Ip similar to previous but a bit better |
| 53187 | 2025-07-16 16:12:01.402 | rhenriques | 3.77 | 4.2 | 26 | Repeat, IPLA raw signal acquired in B3ch29 | Signals look OK, plasma had more successful cycles |
| 53186 | 2025-07-16 16:05:39.391 | rhenriques | -3.5 | 4.2 | 26 | Repeat with cables swapped back to correct position | Signals OK, plasma very similar to previous |
| 53185 | 2025-07-16 15:57:39.357 | rhenriques | -3.46 | 4.2 | 26 | Repeat, with ICOS raw signal acquired in RT3ch15 and B3ch29 (2 MSsp) | RT3ch15 channel not working, forgot to swap cable so default ICOS and ISIN in MARTe chs were swapped |
| 53184 | 2025-07-16 15:47:13.939 | rhenriques | -3.2 | 4.1 | 26 | Repeat (3) 53101 to assess max Ip and wall conditioning, acquire ISIN raw signal in RT3ch15 and B3ch29 (2 MSps) | Ip around 2.3 kA and cycle length still shorter than reference |
| 53183 | 2025-07-16 15:24:13.416 | rhenriques | 1.3 | 3.5 | 17 | Repeat, ISIN (plasma position) raw signal in RT3ch14 and using ICOS integrator for analog integration | There is signal in ISIN but it also looks quite small, plasma keeps evolving |
| 53182 | 2025-07-16 15:01:18.555 | rhenriques | 1.3 | 3.8 | 17 | Repeat, ICOS (plasma position) raw signal connected to RT3ch14 | ICOS signal OK, but seem quite low amplitude compared with EO level, plasma keeps evolving |
| 53181 | 2025-07-16 14:50:44.316 | rhenriques | 1.3 | 3.6 | 17 | Repeat, IPLA raw signal acquired in RT3ch14 (chopper) and integrated (analog) signal in RT2ch4 | IPLA signal looks OK, impurities and plasma temperature keeps evolving |
| 53180 | 2025-07-16 14:41:32.821 | rhenriques | 1.3 | 3.8 | 17 | Repeat, IPLB raw signal connected to RT3ch14 (previously was RT3ch13) | IPLB signal looks reasonable, but needs further checks and filtering |
| 53179 | 2025-07-16 14:12:05.555 | rhenriques | 1.3 | 3.8 | 17 | Repeat, revert changes on density signals | Density signal is OK, impurities and plama temperature keeps evolving |
| 53178 | 2025-07-16 14:01:49.915 | rhenriques | 1.3 | 4 | 17 | Repeat, density signals SINE and COSINE swapped at ATCA board entry to tests ADC channels | Both ADC channels are working, density signal is back (but inverted) |
| 53177 | 2025-07-16 13:51:10.804 | rhenriques | 1.3 | 0 | 17 | Repeat 53173 for conditioning (1.3 kA, 50 cycles of 17 ms) | OK, similar to reference |
| 53176 | 2025-07-16 13:44:51.273 | rhenriques | -2.1 | 0 | 26 | Repeat (2) 53101 to assess max Ip and wall conditioning | Slightly better than previous |
| 53175 | 2025-07-16 13:39:59.731 | rhenriques | 1.8 | 0 | 26 | Repeat (1) 53101 to assess max Ip and wall conditioning | Better than last one like this 53167, but still quite far from reference 53101, density signal still not working |
| 53174 | 2025-07-16 13:31:19.695 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg), no TF | PF currents OK |