Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 53247 | 2025-07-25 16:40:37.954 | rhenriques | -4.9 | 5 | 26 | Repeat connecting IPLB to RT3ch15 (w/o anti-aliasing) | ch15 not behaving properly |
| 53246 | 2025-07-25 16:30:12.004 | rhenriques | -4.7 | 5 | 26 | Repeat with chopper modules in RT3 (as integrators), IPLB in RT3ch13 and IPLA in RT3ch14 | ch13 not working, ch14 OK but EO is quite large |
| 53245 | 2025-07-25 16:11:53.66 | rhenriques | -4.7 | 4.8 | 26 | Repeat to compare chopper with and w/o anti-aliasing, B3ch30 and B3ch31, respectively | Test OK |
| 53244 | 2025-07-25 16:02:11.173 | rhenriques | -4.6 | 4.84 | 26 | Repeat with IPLA on B3ch30 (1.5 nF) and 32 (10 nF) | Test OK |
| 53243 | 2025-07-25 15:50:14.857 | rhenriques | -4.5 | 5 | 26 | Repeat acquiring IPLA raw in B3ch32 (10 nF) and B3ch31 (1.5 nF w/o anti-aliasing filter) | Good test |
| 53242 | 2025-07-25 15:39:09.146 | rhenriques | -4.5 | 4.4 | 26 | Repeat, with 5 chopper modules in B3ch28 to 32 (32 is chopper no.10 from RT3ch10 and 31 has no antialising filter) for testing 1.5 nF input capacitor, 1 Vpp sine wave | Modules are OK |
| 53241 | 2025-07-25 10:22:54.369 | rhenriques | -4.47 | 4.3 | 26 | Repeat (1) 53101 to assess max Ip and wall conditioning, IPLA raw signal connected to chopper module on B3ch32 to assess max signal value | Ip flattop around 3.1 kA, signal spikes go to roughly 100 mV |
| 53240 | 2025-07-25 10:09:51.295 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg), no TF, chopper module no.10 (from RT3ch10) moved to B3ch32 to check ADC input, with 1 Vpp sine wave (also in B3ch31) | PF currents OK |