Session aimPlasma pulses to assess machine conditioning and restart plasma
Session day2025-09-11Operatorrhenriques
Session IDISTTOK_20250911_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
532982025-09-11 11:02:23.013rhenriques0.25017Repeat with similar pressure | mostly the same as previous
532972025-09-11 10:58:20rhenriques0.2017Repeat with similar prefill pressure: aiming at 7e-6 mBar at Admission | Slightly better than previous, but signs of HXRs and still very low Ip
532962025-09-11 10:52:51.717rhenriques0.165017 Repeat with similar prefill pressure: aiming at 7.5e-6 mBar at Admission | very similar to previous
532952025-09-11 10:47:39.913rhenriques0.175017Repeat with more prefill pressure: aiming at 7.5e-6 mBar at Admission | Ip still low, but light emission better than 53293 and no signs of HRXs
532942025-09-11 10:43:20.133rhenriques-0.4017Repeat with lower prefill pressure: aiming at 5e-6 mBar at Admission | More Ip at peak but signs of HXR are observed
532932025-09-11 10:38:58.665rhenriques0.1017Repeat with lower prefill pressure: aiming at 1e-5 mBar at Admission | better, but still very low Ip, no signs of HXR
532922025-09-11 10:29:48.109rhenriques0017Repeat #53168 for wall conditioning (10 semi-cycles with controlled Ip at 1.3 kA), prefill set to 3e-5 mBar before TF on Adm (pressure at MC not behaving correctly) | no Ip, just light emission