Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 53327 | 2025-09-12 14:38:40.178 | rhenriques | 0 | 0 | 0 | Repeat (1) 53101 to assess max Ip and wall conditioning | No plasma, controller failed to trigger |
| 53326 | 2025-09-12 14:25:06.708 | rhenriques | -0.37 | 6.5 | 17 | Repeat | Slightly better |
| 53325 | 2025-09-12 14:21:08.823 | rhenriques | -0.37 | 6 | 17 | Repeat | Mainly the same as previous |
| 53324 | 2025-09-12 14:17:10.154 | rhenriques | -0.39 | 6.5 | 17 | Repeat | Better |
| 53323 | 2025-09-12 14:13:10.75 | rhenriques | -0.37 | 0 | 17 | Repeat with maximum inversion time increased to 5 ms (instead of 2.5 ms) | longer sustained plasma during inversion, better |
| 53322 | 2025-09-12 14:08:37.978 | rhenriques | -0.35 | 0 | 17 | Repeat | Mostly the same again |
| 53321 | 2025-09-12 14:04:22.621 | rhenriques | -0.37 | 0 | 17 | Repeat aiming for correct prefill pressure value (7e-6 mBar) | Similar to previous, prefill pressure still a bit low |
| 53320 | 2025-09-12 13:59:26.729 | rhenriques | 0.371 | 0 | 17 | Repeat | Better Ip peak but prefill pressue was a bit on the low side, still higher post plasma pressure |
| 53319 | 2025-09-12 13:54:36.949 | rhenriques | 0.27 | 0 | 17 | Repeat with correct prefill pressure | Lower Ip and overall performance than 53317, outgas pressure after pulse much lager than in #53317 |
| 53318 | 2025-09-12 13:50:23.162 | rhenriques | 0.2 | 0 | 17 | Repeat after 1h10 of cleaning discharges | Wrong prefill pressure (too high) |
| 53317 | 2025-09-12 09:59:31.482 | rhenriques | -0.37 | 2.2 | 17 | Repeat | Marginally better |
| 53316 | 2025-09-12 09:55:34.261 | rhenriques | -0.38 | 0 | 17 | Repeat | Moslty the same as previous |
| 53315 | 2025-09-12 09:51:20.856 | rhenriques | -0.372 | 0 | 17 | Repeat | slightly better |
| 53314 | 2025-09-12 09:47:20.14 | rhenriques | -0.36 | 4.3 | 17 | Repeat | still improving |
| 53313 | 2025-09-12 09:43:22.439 | rhenriques | -0.33 | 5 | 17 | Repeat | Improving |
| 53312 | 2025-09-12 09:39:25.322 | rhenriques | 0.29 | 2 | 17 | Repeat | Still improving but at very slow pace |
| 53311 | 2025-09-12 09:35:27.006 | rhenriques | 0.25 | 2 | 17 | Repeat | Negative semi-cycles are improving |
| 53310 | 2025-09-12 09:31:30.369 | rhenriques | 0.25 | 2 | 17 | Repeat | Some positive cycles starting to pickup as well, but not too different than previous pulse |
| 53309 | 2025-09-12 09:27:33.244 | rhenriques | 0.28 | 2 | 17 | Repeat | Mostly the same, although pressure after pulse seems to be lower |
| 53308 | 2025-09-12 09:23:15.32 | rhenriques | -0.244 | 2 | 17 | Repeat with 30 semi-cycles (instead of 20) | Mostly the same |
| 53307 | 2025-09-12 09:19:17.203 | rhenriques | 0.23 | 0 | 17 | Repeat with 20 semi-cycles (instead of 10) | Mostly the same, the extra 10 are only negative cycles |
| 53306 | 2025-09-12 09:14:58.759 | rhenriques | 0.23 | 2 | 17 | Repeat | Mostly the same |
| 53305 | 2025-09-12 09:09:15.195 | rhenriques | 0.245 | 2 | 17 | Repeat with a slight increase on prefill pressure | smaller HXRs signal, Ip is lower due to the increased pressure, negative cycles seems to be picking up |
| 53304 | 2025-09-12 09:04:10.359 | rhenriques | 0.36 | 0 | 17 | Repeat | Plasma ended early, Ip is slightly better, but prefill pressure is going a bit to the low side |
| 53303 | 2025-09-12 09:00:10.907 | rhenriques | 0.29 | 0 | 17 | Repeat | Mostly the same, maybe a bit better for the negative cycles |
| 53302 | 2025-09-12 08:53:50.459 | rhenriques | 0.29 | 0 | 17 | Repeat | Marginally better |
| 53301 | 2025-09-12 08:49:14.691 | rhenriques | 0.25 | 0 | 17 | Repeat, with a bit less prefill pressure | More similar to 53298, pressure is slighlty lower |
| 53300 | 2025-09-12 08:34:34.993 | rhenriques | 0.137 | 0 | 17 | Repeat #53168 for wall conditioning (10 semi-cycles with controlled Ip at 1.3 kA), prefill set to 7e-6 mBar on Adm (pressure at MC not behaving correctly) | Same as 53298, but at bit less Ip |
| 53299 | 2025-09-12 08:24:15.964 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg), no TF, tomography: same as in #53291 | PF currents OK |