| Session aim | Test MARTe and PF coils, then peform a series of plasma pulses and Spectrometer calibration pulse | | Session day | 2025-01-29 | Operator | fernando | | Session ID | ISTTOK_2025129_1 | Coordinator | rhenriques |
|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 51684 | 2025-01-29 17:10:59.101 | rhenriques | 0 | 0 | 0 | Calibrate spectrometer with Hg light bulb, C0=0, C1=1, C2=0, C3=0 | Good | | 51683 | 2025-01-29 16:30:33.651 | rhenriques | 0 | 0 | 0 | Trying again this time with DNS server set | Acquisition storage in SDAS successful. Signal name is POST.PROCESSED.TEST | | 51682 | 2025-01-29 15:40:59.898 | rhenriques | 0 | 0 | 0 | Trying again | Acquisition successful but it did not store data in SDAS, because the computer had no DNS resolver | | 51681 | 2025-01-29 15:36:57.534 | rhenriques | 0 | 0 | 0 | Run informatic pulse to test acquistion and triggering of SARSPEC spectrometer | Forgot to set the spectrometer ready for trigger | | 51680 | 2025-01-29 14:18:49.968 | rhenriques | 0 | 0 | 0 | Repeat with fixed cabling | OK, oscillations are seen in both sine and cosine signals | | 51679 | 2025-01-29 14:14:48.228 | rhenriques | 0 | 0 | 0 | Repeat with oscillations in the interferometer to induce fake phase shifts | OK, cosine amplitude is low, one cable at interferometer seemed slightly disconnected | | 51678 | 2025-01-29 13:48:11.862 | rhenriques | 0 | 0 | 0 | Informatic pulse to test MARTe and FireSignal communication | OK |
|