Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
145052007-03-07 17:28:39.515pduarte4220R=0,5. ELCO = 190V. Feedback on Vertical. Pre-programed Horizontal field. 3rd cycle. Comb puffing.