The downloading of the charts may take some seconds...

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
162312007-10-11 15:52:23.638pduarte0.61.92140 turns primary. R = 0,2ohm. ELCO = 220V. P=1,80x10^(-4)mbar. Pre-programmed V field and H field.