The downloading of the charts may take some seconds...

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
182262008-04-09 16:06:18.346pduarte3.33.24940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,65x10^(-4)mbar. Mixed-feedback on H field with kp+=2510091 and setpoint=5 and Pre-programmed V field.