The downloading of the charts may take some seconds...

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
195442008-07-11 14:06:36.355pduarte1.23.24840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.