The downloading of the charts may take some seconds...

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
195752008-07-28 13:34:11.263pduarte12.52640 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. ITOR=5900A=>valor=1100