The downloading of the charts may take some seconds...

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
214342009-03-05 11:41:03.177pduarte32.89340 turns primary. R = 0,4ohm. ELCO = 220V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field.