The downloading of the charts may take some seconds...

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
332032012-09-21 15:09:44.18pduarte3.53.73028 turns primary. ELCO = 200V. P=1,60x10^(-4)mbar. r position control. Puffing. double ball pen = 60. IB.